Naslov Numerička analiza toplinske akumulacije zgrade na svojstva i potrošnju sustava grijanja
Naslov (engleski) Numerical analysis of the thermal accumulation of the building on the characteristics and consumption of the heating system
Autor Ana Maria Prijić
Mentor Boris Delač (mentor)
Mentor Branimir Pavković (komentor)
Član povjerenstva Vedran Mrzljak (predsjednik povjerenstva)
Član povjerenstva Tomislav Mrakovčić (član povjerenstva)
Član povjerenstva Boris Delač (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Sveučilište u Rijeci Tehnički fakultet Rijeka
Datum i država obrane 2024-09-19, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Strojarstvo Procesno energetsko strojarstvo
Sažetak Za potrebe izrade diplomskog rada analizirane su mogućnosti simulacije toplinskog modela novogradnje obiteljske kuće smještene u okolici grada Rijeke s korisnom površinom od 273,24 m2. Analiza utjecaja toplinske akumulacije ispitana je kroz tri razine detaljnosti, ovisno o brojnosti toplinskih zona simulacijskog modela, te dviju metoda građenja konstrukcije građevnih elemenata zgrade, klasične i montažne metode građenja. Za provedbu simulacija toplinskih modela i određivanje potrebne toplinske
... Više energije za grijanje i hlađenje kuće se koristio 3D model kojega je potrebno toplinski ugoditi prema zadanim radnim parametrima, rubnim uvjetima itd., a s vremenskim korakom od 60 minuta za referentnu godinu. Toplinskim zonama zgrade definirano je idealno grijanje i hlađenje pri neograničenom učinku s projektiranom temperaturom grijanja u prostorijama od 20 °C a kod hlađenja s temperaturom 24 °C uz relativnu vlažnost od 50 %. Ovisno o vremenskom koraku simulacija toplinskog modela, izvršene su analize dobivenih podataka s vremenskim korakom od 30 min, 10 min i 5 min. Dodijeljeni su unutarnji dobici od 5 W/m2 po površini toplinske zone te je primijenjena infiltracija i minimalno provjetravanje prostora od 0,64 h-1 za sve toplinske zone. Promatran je utjecaj na toplinsku akumulaciju s obzirom na prekid grijanja zimi u noćnom periodu od 22 do 6 sati. Na isti način ispitan je utjecaj na toplinsku akumulaciju s obzirom na prekid hlađenja s prekidom rada od 22 h do 6 h ujutro, uz uvjet da je temperatura okoline manja od temperature zraka toplinske zone. Također ispitana je primjena prirodne ventilacije ljeti u noćnom periodu. Za sve izvedbe definirana je sezona grijanja koja traje od prvog do kraja četvrtog mjeseca u prvom dijelu godine te od desetog do kraja dvanaestog mjeseca, a period hlađenja je od petog do kraja devetog mjeseca. Na obiteljskoj kući nalazi se aktivno unutarnje zasjenjenje na svim prozorima te vanjsko zasjenjenje na prozorima koji su smješteni na južnom pročelju kuće. Sakrij dio sažetka
Sažetak (engleski) For the purposes of the thesis, the possibilities of simulating the thermal model of a new family house located in the vicinity of the city of Rijeka with a usable area of 273.24 m2 were analyzed. The analysis of the influence of thermal accumulation was examined through three levels of detail, depending on the number of thermal zones of the simulation model, and two building, classical and prefabricated construction methods. A 3D model was used to perform thermal model simulations and
... Više determine the required thermal energy for heating and cooling the house, which needs to be thermally adjusted according to the given operating parameters, boundary conditions, etc., with a time step of 60 minutes for the reference year. The thermal zones of the building define ideal heating and cooling with unlimited effect with a designed temperature in the rooms of 20 °C for heating and a temperature of 24 °C for cooling with a relative humidity of 50%. Depending on the time step of the thermal model simulations, the obtained data were analyzed with a time step of 30 min, 10 min and 5 min. Internal gains of 5 W/m2 per surface of the thermal zone, and natural ventilation of 0.64 h-1 was applied for all thermal zones. The impact on heat accumulation was observed due to the interruption of heating in the winter in the night period from 10 pm to 6 am. In the same way, the impact on the heat accumulation was examined with regard to the interruption of cooling with the interruption of operation from 10 pm to 6 am, with the condition that the ambient temperature is lower than the air temperature of the thermal zone. The use of natural ventilation in the summer at night was also tested. For all versions, a heating season is defined that lasts from the first to the end of the fourth month in the first part of the year and from the tenth to the end of the twelfth month, and the cooling period is from the fifth to the end of the ninth month. The family house has active internal shading on all windows and external shading on the windows located on the southern facade of the house. Sakrij dio sažetka
Ključne riječi
grijanje
hlađenje
toplinska energija
prirodna ventilacija
projektna temperatura
simulacijski model
Ključne riječi (engleski)
heating
cooling
thermal energy
natural ventilation
design temperature
simulation model
Jezik hrvatski
URN:NBN urn:nbn:hr:190:532767
Studijski program Naziv: Strojarstvo Vrsta studija: sveučilišni Stupanj studija: diplomski Akademski / stručni naziv: magistar/magistra inženjer/inženjerka strojarstva (mag. ing. mech.)
Vrsta resursa Tekst
Način izrade datoteke Izvorno digitalna
Prava pristupa Otvoreni pristup
Uvjeti korištenja